• Supercritical Water Environment Corrosion Testing System
    Supercritical Water Environment Corrosion Testing System

    Scale:lMax working temperature: 650℃lMax working pressure: 30MPalTest cell capacity: 2.5LlMax flow rate: 15L/hFunction:lLong term corrosion testlCP release behavior testlStress corrosion cracking testlElectrochemistry testAchievements:Screening and qualif

    View Details
  • AC600 Secondary-side Passive Residual Heat Removal System (PRHRS) Test Facility
    AC600 Secondary-side Passive Residual Heat Removal System (PRHRS) Test Facility

    Scale:lPower: 500MW, Scaling factor: 1/390lDesign Pressure: 8.6MPa, Design Temperature: 316℃lAir-cooler funnel height: 12.8mFunction:lChinese Advanced PWRs Secondary-side PRHRS comprehensive experimentsAchievements:lAC600 Secondary-side PRHRS experimentsl

    View Details
  • Control Rod Drive Line Cold Test Facility
    Control Rod Drive Line Cold Test Facility

    Scale:lOperation pressure: ≤1MPa, operation temperature: ≤80℃lFlow rate in loop: 700m3/h, pressure head of pump: 65m H2OFunction:lFor cold test on hydraulic property of reactor control rod drive line, test on hydraulic characteristics of fue

    View Details
  • Freon Test Facility
    Freon Test Facility

    Scale:lPower: 500MWlPressure:üDesign Pressure: 4.0MPaüOperation Pressure: 2.77MPalTemperature:üDesign Temperature: 120℃üOperation Temperature: 89℃lFlow rate:üMain Pump Flow Rate: 60t/hüTest Section Flow Rate: 25t/hFunction:lR

    View Details
  • Multi-Point Actuating Seismic Test Facility
    Multi-Point Actuating Seismic Test Facility

    Scale:lFour actuators with Max. output force: 63KNlFrequency range of hydraulic system: 0.1~100HzlMaximum displacement of the actuator: ±125mmlDepth of the pit:15m with 12m undergroundFunction:lUsed for seismic test research of slim and flexible st

    View Details
1 2